Applications
For use with Airmar’s Ultrasonic Transducers.
To aid in designing ultrasonic systems.
Allows the designer to quickly and easily transmit and
receive echoes.
Features
Jumper selectable pulse width and frequency for optimal
interfacing.
Transmit pulse is amplified to 200 - 500 Vpp via a power
MOSFET and transformer.
Received echoes can be viewed at X1, X10, X100, or
X1000 amplification.
Set Up
J1—Set the jumper at the position appropriate for the
model being tested (see Table 1 and Figure 1). This selects
the initial value for the pulse rate.
J2—Set the jumper at the position appropriate for the model
being tested. This selects the initial value for frequency.
J8—Set the jumper to the proper voltage range for the
model being tested.
J7—Set the jumper for the desired echo amplification:
X1, X10, X100, or X1000.
J5—Connect the transducer.
J6—Connect an oscilloscope.
J4—Connect a 15VDC power supply capable of delivering
at least 125mA.
Jumper Position & Adjustability
The available models with their corresponding pulse width,
frequency, and voltage range adjustability are shown on
Table 1.
NOTE: These values are approximate.
OPERATING INSTRUCTIONS
T1 Development Kit
17-143 rev. 03 08/20/12
WARNING: The power supply must be OFF before
making electrical connections.
WARNING: The power supply requires a 0.5 amp
fast-blow fuse or circuit breaker.
IMPORTANT: Please read the instructions completely
before proceeding.
Table 1: Jumper Position and Adjustability
Model
J1
Pulse Rate
J2
Frequency
J8
Voltage
POT1
Pulse Width Range
POT2
Frequency Range
POT3
Voltage Range
AR-30
C1 (3Hz) C9
<100kHz
120 - 2400µs 25 - 34kHz 204 - 450Vpp
AR-41
C2 (5Hz) C10
<100kHz
80 - 1600µs 32 - 46kHz 204 - 516Vpp
AR-50
AT-50
C3 (6Hz) C11
<100kHz
60 - 1200µs 46 - 60kHz 172 - 452Vpp
AT-75
C4 (10 Hz) C12
<100kHz
50 - 1000µs 64 - 83kHz 196 - 508Vpp
AT-120
C5 (25Hz) C13
>100kHz
40 - 800µs 115 - 149kHz 90 - 248Vpp
AT-200
C6 (25Hz) C14
>100kHz
16 - 320µs 173 - 228kHz 90 - 260Vpp
AT-225
C7 (25Hz) C15
>100kHz
16 - 320µs 202 - 265kHz 90 - 256Vpp
AT-300
C8 (25Hz) C16
>100kHz
16 - 320µs 296 - 357kHz 90 - 252Vpp